No. |
種別 |
タイトル |
1 |
写真 |
The status of the 5th floor in the Reactor Building of Unit 4 Rebar deformed upward [pictured on November 8, 2011]
(上位階層ページタイトル/会議名: Survey result of damages to air-conditioning ducts etc. in the Reactor Building Unit 4 Fukushima Daiichi Nuclear Power Station)
情報提供機関: 東京電力
掲載日/会議開催日: 2011-11-10
|
2 |
写真 |
The status of the 5th floor in the Reactor Building of Unit 4 Floor curled up [pictured on November 8, 2011]
(上位階層ページタイトル/会議名: Survey result of damages to air-conditioning ducts etc. in the Reactor Building Unit 4 Fukushima Daiichi Nuclear Power Station)
情報提供機関: 東京電力
掲載日/会議開催日: 2011-11-10
|
3 |
写真 |
The status of the 5th floor in the Reactor Building of Unit 4 Floor pushed up [pictured on November 8, 2011]
(上位階層ページタイトル/会議名: Survey result of damages to air-conditioning ducts etc. in the Reactor Building Unit 4 Fukushima Daiichi Nuclear Power Station)
情報提供機関: 東京電力
掲載日/会議開催日: 2011-11-10
|
4 |
写真 |
The status of the 5th floor in the Reactor Building of Unit 4 Wire mesh, inlet of the air-conditioning at Reactor Well was bent to the reverse direction [pictured on November 8, 2011]
(上位階層ページタイトル/会議名: Survey result of damages to air-conditioning ducts etc. in the Reactor Building Unit 4 Fukushima Daiichi Nuclear Power Station)
情報提供機関: 東京電力
掲載日/会議開催日: 2011-11-10
|
5 |
写真 |
The status of the 5th floor in the Reactor Building of Unit 4 Wire mesh, inlet of the air-conditioning at Spent Fuel Pool was bent to the reverse direction [pictured on November 8, 2011]
(上位階層ページタイトル/会議名: Survey result of damages to air-conditioning ducts etc. in the Reactor Building Unit 4 Fukushima Daiichi Nuclear Power Station)
情報提供機関: 東京電力
掲載日/会議開催日: 2011-11-10
|
6 |
写真 |
The status of the 4th floor in the Reactor Building of Unit 4 Rubbles from air-conditioning ducts [pictured on November 8, 2011]
(上位階層ページタイトル/会議名: Survey result of damages to air-conditioning ducts etc. in the Reactor Building Unit 4 Fukushima Daiichi Nuclear Power Station)
情報提供機関: 東京電力
掲載日/会議開催日: 2011-11-10
|
7 |
写真 |
The status of the 4th floor in the Reactor Building of Unit 4 Rubbles from air-conditioning ducts [pictured on November 8, 2011]
(上位階層ページタイトル/会議名: Survey result of damages to air-conditioning ducts etc. in the Reactor Building Unit 4 Fukushima Daiichi Nuclear Power Station)
情報提供機関: 東京電力
掲載日/会議開催日: 2011-11-10
|
8 |
写真 |
The status of the 4th floor in the Reactor Building of Unit 4 Floor pushed down [pictured on November 8, 2011]
(上位階層ページタイトル/会議名: Survey result of damages to air-conditioning ducts etc. in the Reactor Building Unit 4 Fukushima Daiichi Nuclear Power Station)
情報提供機関: 東京電力
掲載日/会議開催日: 2011-11-10
|
9 |
写真 |
The status of the 4th floor in the Reactor Building of Unit 4 Rubbles from air-conditioning ducts [pictured on November 8, 2011]
(上位階層ページタイトル/会議名: Survey result of damages to air-conditioning ducts etc. in the Reactor Building Unit 4 Fukushima Daiichi Nuclear Power Station)
情報提供機関: 東京電力
掲載日/会議開催日: 2011-11-10
|
10 |
写真 |
The status of the 4th floor in the Reactor Building of Unit 4 Rubbles from air-conditioning ducts [pictured on November 8, 2011]
(上位階層ページタイトル/会議名: Survey result of damages to air-conditioning ducts etc. in the Reactor Building Unit 4 Fukushima Daiichi Nuclear Power Station)
情報提供機関: 東京電力
掲載日/会議開催日: 2011-11-10
|
11 |
写真 |
The status of the 4th floor in the Reactor Building of Unit 4 Rubbles from air-conditioning ducts (no air-conditioning ducts above) [pictured on November 8, 2011]
(上位階層ページタイトル/会議名: Survey result of damages to air-conditioning ducts etc. in the Reactor Building Unit 4 Fukushima Daiichi Nuclear Power Station)
情報提供機関: 東京電力
掲載日/会議開催日: 2011-11-10
|
12 |
写真 |
The status of the 4th floor in the Reactor Building of Unit 4 The original place of installation of air- conditioning ducts [pictured on November 8, 2011]
(上位階層ページタイトル/会議名: Survey result of damages to air-conditioning ducts etc. in the Reactor Building Unit 4 Fukushima Daiichi Nuclear Power Station)
情報提供機関: 東京電力
掲載日/会議開催日: 2011-11-10
|
13 |
写真 |
The status of the 3rd floor in the Reactor Building of Unit 4 Damages to the floor [pictured on November 8, 2011]
(上位階層ページタイトル/会議名: Survey result of damages to air-conditioning ducts etc. in the Reactor Building Unit 4 Fukushima Daiichi Nuclear Power Station)
情報提供機関: 東京電力
掲載日/会議開催日: 2011-11-10
|
14 |
写真 |
The status of the 3rd floor in the Reactor Building of Unit 4 Floor pushed down (in front is rubbles from air-conditioning ducts) [pictured on November 8, 2011]
(上位階層ページタイトル/会議名: Survey result of damages to air-conditioning ducts etc. in the Reactor Building Unit 4 Fukushima Daiichi Nuclear Power Station)
情報提供機関: 東京電力
掲載日/会議開催日: 2011-11-10
|
15 |
写真 |
The status of the 3rd floor in the Reactor Building of Unit 4 Rubbles from air-conditioning ducts [pictured on November 8, 2011]
(上位階層ページタイトル/会議名: Survey result of damages to air-conditioning ducts etc. in the Reactor Building Unit 4 Fukushima Daiichi Nuclear Power Station)
情報提供機関: 東京電力
掲載日/会議開催日: 2011-11-10
|
16 |
写真 |
The status of the 3rd floor in the Reactor Building of Unit 4 Rubbles from air-conditioning ducts [pictured on November 8, 2011]
(上位階層ページタイトル/会議名: Survey result of damages to air-conditioning ducts etc. in the Reactor Building Unit 4 Fukushima Daiichi Nuclear Power Station)
情報提供機関: 東京電力
掲載日/会議開催日: 2011-11-10
|
17 |
写真 |
The status of the 3rd floor in the Reactor Building of Unit 4 Rubbles from air-conditioning ducts [pictured on November 8, 2011]
(上位階層ページタイトル/会議名: Survey result of damages to air-conditioning ducts etc. in the Reactor Building Unit 4 Fukushima Daiichi Nuclear Power Station)
情報提供機関: 東京電力
掲載日/会議開催日: 2011-11-10
|