Number of page views | : | 33 |
Title | Partial damage to temperature gauge cables for the Reactor Pressure Vessel (RPV) found during the Fukushima Daiichi Nuclear Power Station Unit 3 primary containment vessel (PCV) internal investigation (reference material) | ||||
Publisher | TEPCO | ||||
Issued date | 2017-11-30 | ||||
Language | eng | ||||
Page | 6p. | ||||
Type | presentation | ||||
File Format | |||||
Taxonomy | 5-1-1-1 Radiation survey/monitoring/energy spectra | ||||
Taxonomy(Computer Assigned) | 5-1-1 Zone diagnostics | ||||
Subject/Session_name | Fukushima Daiichi Nuclear Power Station, Unit 3, CONTAINMENT SHELLS, PCV | ||||
Information source | Go to the saved web page | ||||
Upper page title | Partial damage to temperature gauge cables for the Reactor Pressure Vessel (RPV) found during the Fukushima Daiichi Nuclear Power Station Unit 3 primary containment vessel (PCV) internal investigation | ||||
Related sites |
|
||||